nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2016, 01, v.32;No.144 30-32
一体式湿式电除尘器流场的数值模拟与优化设计
基金项目(Foundation):
邮箱(Email):
DOI:
发布时间: 2016-02-15
出版时间: 2016-02-15
移动端阅读
摘要:

湿式电除尘器流场的均匀性对湿式电除尘器的性能及效率具有重要意义,而湿式电除尘器电场各个分区的流量偏差和通过每个阳极管流量的相对均方根差是体现其内部流场均匀性的两个重要指标。采用CFD数值模拟技术,对魏桥邹平燃煤电厂660 MW机组配套湿式电除尘器的内部流场设计进行研究分析,结果表明,通过设置导流装置和整流格栅可以分别优化湿式电除尘器电场各个分区的流量偏差和通过每个阳极管流量的相对均方根差,从而提高湿式电除尘器的性能及效率。

Abstract:

The uniformity of the flow field distribution of wet electrostatic precipitator has important significance on its performance and efficiency,the electric field flow distribution and the relative RMS through each anode tube flow are two important indicators to reflect its internal flow field uniformity. Using CFD numerical simulation technology to analyze the internal flow field design of a coal- fired power plant 660 MW unit supporting wet electrostatic precipitator. The results show that the electric field flow distribution and the relative RMS through each anode tube flow of wet electrostatic precipitator can respectively be optimized by setting deflector and Rectifier grille,thus improve the performance and efficiency of wet electrostatic precipitator.

基本信息:

中图分类号:X773

引用信息:

[1]彭华宁.一体式湿式电除尘器流场的数值模拟与优化设计[J].电力科技与环保,2016,32(01):30-32.