湿式电除尘器流场的均匀性对湿式电除尘器的性能及效率具有重要意义,而湿式电除尘器电场各个分区的流量偏差和通过每个阳极管流量的相对均方根差是体现其内部流场均匀性的两个重要指标。采用CFD数值模拟技术,对魏桥邹平燃煤电厂660 MW机组配套湿式电除尘器的内部流场设计进行研究分析,结果表明,通过设置导流装置和整流格栅可以分别优化湿式电除尘器电场各个分区的流量偏差和通过每个阳极管流量的相对均方根差,从而提高湿式电除尘器的性能及效率。
Abstract:The uniformity of the flow field distribution of wet electrostatic precipitator has important significance on its performance and efficiency,the electric field flow distribution and the relative RMS through each anode tube flow are two important indicators to reflect its internal flow field uniformity. Using CFD numerical simulation technology to analyze the internal flow field design of a coal- fired power plant 660 MW unit supporting wet electrostatic precipitator. The results show that the electric field flow distribution and the relative RMS through each anode tube flow of wet electrostatic precipitator can respectively be optimized by setting deflector and Rectifier grille,thus improve the performance and efficiency of wet electrostatic precipitator.
[1]郭程程,李娜.火电厂石膏雨治理方案的研究与应用[J].电力科技与环保,2013,29(2):28-30.
[2]金定强,马修元,周凯,等.湿式静电除尘器流场的数值模拟与优化设计[J].电力科技与环保,2015,31(1):32-35.
[3]马双忱,王梦璇,蔡晓彤,等.FLUENT在燃煤电厂大气污染控制领域的应用研究进展[J].电力科技与环保,2011,27(6):1-5.
[4]王福军.计算流体动力学分析:CFD软件原理与应用[M].北京:清华大学出版社,2004.
[5]陶文铨.数值传热学[M].西安:西安交通大学出版社,1999.
[6]党小庆,谢照亮,胡红胜,等.燃煤电厂袋式除尘器入口烟道烟气温度偏差调整[J].电力科技与环保,2012,28(4):20-22.
[7]沈丹,仲兆平,过小玲.600 MW电厂SCR烟气脱硝反应器内不同导流板的流场数值模拟[J].电力环境保护,2007,23(1):42-45.
[8]李雪梅.电除尘器内部气流分布特性的数值研究[D].吉林:东北电力大学,2009.
基本信息:
中图分类号:X773
引用信息:
[1]彭华宁.一体式湿式电除尘器流场的数值模拟与优化设计[J].电力科技与环保,2016,32(01):30-32.
2016-02-15
2016-02-15